Slide Stainer Series

LSS 850 Slide Stainer

Features: LSS-850 automatic slide stainer can preset the staining process according to different tissue types, intelligent software control the staining process, reduce the staining difference caused

Features: 

LSS-850 automatic slide stainer can preset the staining process according to different tissue types, intelligent software control the staining process, reduce the staining difference caused by operation, through the program presets the staining frame in accordance with the set program in each rack to achieve the purpose of automatic staining.

Main Technical Data:

1Number of Station: 

    32 Stations: Including 

    5 washing stations (can be set as reagent stations according to customers' requirements). 

    6 uploading/downloading Stations, 

    3 Oven stations, up to 31 reagent stations. 

2Water station: 5 stations. 

3Visible planar construction is easy to observe the liquid level height of each tank position; Built-in LED lighting is easy observation of the staining process.

4With 12.1inch color touch screen and English operating interface. It no need stop when adjusting the parameters. 

5Hot plate temperature: 25 to 95

6Editable program: Can store 200 editable programs, 200 steps/program.Each step setting time: 1 second -23 hours 59 minutes and 59 seconds

7Each step can be setting 3 working modes for Precise time control: Normal, Priority (priority processing the lifting), Precise mode (robotic arm standing by to wait for lifting the rack) 

8Parameters: screen that can shows the steps of the process in progress. 

9XYZ three-axis manipulator combined movement, highly intelligent multi-threaded task scheduling program, high efficiency, can uploading and running 12 baskets concurrently. The staining speed is 720 slides/h. 

10The mechanical arm can be set 3 working modes: Drainage, Shaking, Agitation. And can freely setting the parameters.

1112 programs can be run simultaneously and can make frozen sections, HE staining and PAPA staining. 

12It can be paused or started the running program at any time when instrument working. 

13It can be cancel the running staining program at any time, or can be renew the canceled running program, and the renewed program will continue to run from its pre-undo state. 

1410 shortcut programs can be set on the main interface; Each step can be setting 3 working modes. 

15Conventional HE staining, fast frozen HE staining and PAPA staining can be performed individually or simultaneously 

16the basket is uploading and downloading with drawer type station. You can setting uploading/ downloading station freely. Various combinations to meet the needs of different situations. 

17The uploading station has a detection sensor to automatically detect the slide rack status in the station; With abnormal open drawer alarm and delayed voice reminder function, drawer open timeout reminder time 1-120 seconds adjustable. 

18Any tank starting function. 

19Intelligent staining time adjustment. It can be set according to the staining days or the number of baskets, automatically adjust the staining time, and the single staining time can be adjusted at any time. 

20On-demand water supply. Real-time detection of water intake status in the running water tank.

21The instruments have a built-in water flow control knob, which can adjust the water flow according to the water pressure to ensure adequate washing.

22Reagent change remind and management functions, it can remind the operator to pay attention to and replace the corresponding reagent in real time according to the days or times of reagent use. Reagent usage is marked in different colors on the touch screen. 

23The staining time is intelligently adjusted according to the reagent use time and the number of staining pieces. 

24Fast running speed, the fastest to complete 1s differentiation. 

25Activated carbon filter + air purification system ensure a safe working environment. 

26When the equipment is operating, the cover is abnormally opened and the alarm is raised, and the manipulator stops running. This function can open or close. 

27With artificial voice prompt alarm function, after failure or completion of work, voice prompt, prompt frequency, volume, number of times can be adjusted, failure occurs on the main page to prompt and display the solution guide, to remind technical personnel to operate in time. 

28with the running status query function, you can understand the current execution of the step, remaining time and station distribution and other information. 

29with a quality control module, including quality control Settings and overview, change of reagent records, running program history, reagent use details and other modules. 

30remote intelligent monitoring: with remote alarm, remote monitoring function, you can monitor through the web page or APP three ways, real-time understanding of the operating status of the instrument, USB interface configuration, can export Excel quality control table. 

31with two USB interfaces, you can export quality control data, you can upgrade the equipment, update operations. 

32with the administrator and ordinary user login mode, can set the password, the administrator account has the highest authority, can be assigned to other account permissions, query Settings and modify operations. 

33triple sound and light alarm system: English artificial voice alarm system, control panel synchronous light prompt, light color three, the main interface synchronous text display solution guide. 

34basket capacity20pcs/sheet, one running can handle 3 baskets with 60 slides. 

35tank capacity850m

Net Weight: 167kg Dimensions: 1180*730*680mm